![]() In addition, use the anti-oxidant grease pack for the wire harness connectors X2 1Ģ Circuit Board Diagram Main Wire Harness (P2) Note: J3 is for use only with the EX Output Module. For additional protection, install the provided foam gasket between the keypad and the back box. For outdoor installations, use a UL Listed weatherproof back box and seal the wire entry locations with silicone and provide a drain hole. An appropriate range is typically between 48 and 52 inches on center off the floor. Mounting height can vary depending on requirements. Mounting the Keypad The keypad is designed to be fl ush mounted using a standard UL Listed single-gang electrical box. The 2000e/eM keypads were evaluated by UL, in Wiegand Front End mode, for use only with the Hub Max II and Hub MiniMax II products used in conjunction with the Wiegand Interface Module. The locking device and all inputs and outputs are connected to the control panel. The control panel maintains the users and programming options and makes all the access control decisions. When you enter a code on the keypad it is then sent to the control panel as Wiegand card data, depending on which format you ve programmed it for. Wiegand Front End Mode: In Wiegand Front End mode, a separate Wiegand Access Control panel is required. The 2000e/eM keypads were evaluated by UL, in Secured Series Front End mode, for use only with the Hub Max II and Hub MiniMax II products. The locking device and all inputs and outputs are connected to the controller. The Secured Series Controller maintains the users and programming options and makes all the access control decisions. Secured Series Front End Mode: In Secured Series Front End mode, a Secured Series Controller is required. The lock and all other inputs and outputs are connected directly to the keypad. In this mode, all the users and other programming options are maintained within the keypad and no additional controller is required. ![]() Standalone Mode: By default, the keypad is programmed for Standalone Mode. Refer to the programming section for details about selecting each mode. Below is a brief explanation of each mode. If the keypad still does not work after troubleshooting, please call the Technical Services department at Keypad Operating Modes The 2000e/2000eM keypad has three operating modes: Standalone Mode, Secured Series Front End Mode and Wiegand Front End Mode. 22 AWG 1.0x ( 1 is the major version 0 is the minor version x is a minor version, reserved for bug fi xes, which is indicated with a letter, such as a.) Technical Support DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. 30VDC (Main & Aux) Normally Open Dry Contact Normally Closed Dry Contact 4.50 H x 2.75 W x 0.60 D Indoor or Outdoor -31 F to 151 F (-35✬ to 66 C) Stranded and Shielded 1000 Ft. Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Keypad with Output Expansion Module (2000-8EX) Current Requirements (Max) Relay Contact Rating REX Input Door Position Switch Input Mechanical Dimensions Environment Temperature Tolerance Front End Cable Type Front End Distance and Wire Gauge Firmware Version Specifications VDC VAC VDC VAC 10V: 85mA 12V: 150mA 30V: 115mA 24V: 200mA VDC VAC 10V: 230mA 12V: 500mA 30V: 390mA 24V: 700mA Note: This is total maximum current including keypad and output module. 1 2000e & 2000eM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |